No.120 MELT FLOW INDEX TESTERS
(MFR, MFI, MVR, Flow Properties)
No.120-FWP MELT FLOW INDEX TESTER (MANUAL)
Related Test Standards: JIS K6719-1/2, K6921-2, K6922-2, K6923-1, K6924-1, K6926-2, K7210, ASTM D1238, ISO 1133
- Manual Type, Selectable from FWP and FWP-W (Load Lifting/Lowering is Automatic)
- ±0.3℃ Temp. Distribution from 10 to 70mm Above the Die as per ISO-1133-2
- Accurate Reading in ±0.0018mm of the Piston Travel Distance.
- Graph Display of the Temperature Transition in the Cylinder and MFR.
- Sample Cut Off Timing is Guided Visually and Audibly (Method A).
- MFR Value is Automatically Calculated and Displayed on the Touch Panel.
- Rotary Encoder's Precision (Output Pulse) is Verifiable.
- Easy Identification of Individual Tester by Setting Unit Number on the Software.
Specification
Model | No.120-FWP MELT FLOW INDEX TESTER (MANUAL) No.120-FWP-W MELT FLOW INDEX TESTER (Load Lifting/Lowering is Automatic) |
Hanging | 1 Hanging |
Die | φ2.095 ± 0.005 mm, L8.000 ± 0.025 mm |
Piston | Head Diameter φ9.474 ± 0.007 mm, Head Length L6.35 ± 0.10 mm |
Cylinder | Inner φ9.550 ± 0.007 mm, L160 mm |
Temperature Range | Max. 400 °C |
Initial Weight | 0.325 kgf |
Additional Weight | 1.20 〜 21.60 *Please refer to below |
Test Method | Method A: Manual (Option: Automatic Cutter) Method B: Automatic |
Data Processing | Method A: Automatic (Measuring the weight of the cut off specimen is done by hand) Method B: Automatic |
Method B Measuring | Rotary Encoder |
Standard Specification | SD Card Slot, LAN Port |
Options | Mini Printer, Method A Air Pressure Type Automatic Cutter, Manual Type Die Plug, Safety Cover with Interlock Attached, Half Die, Air Pressure Type Automatic Loader (No.120-FWP-W) Additional Weight ( 1.20, 2.16, 3.80, 5.00, 10.00, 21.60 kgf.) |
Accessories | Cleaning Rod (Die & Cylinder), Injection Rod, Funnel, Die Gauge, Method A Cutting Knife, Spirit Level, Gauze |
Power Source | AC 100 V, 1-Phase, 15 A, 50/60 Hz or AC 200 V, 1-Phase, 10 A, 50/60 Hz |
Air Source | 0.5 MPa or More (For Method A Pneumatic Type Weight Loading Device Specification) |
Dimensions / Weight (approx.) |
No.120FWP: W660 × D450 × H1,020 mm, 75 kg (W2.17 × D1.48 ×H3.35 ft, 165 lbs) No.120FWP-W: W710 × D450 × H1,060 mm, 120 kg (W2.33 × D1.48 ×H3.48 ft, 265 lbs) |
The specifications above are subject to change without notice.
No.120-SAS MELT FLOW INDEX TESTER (SEMI-AUTOMATIC)
Related Test Standards: JIS K6719-1/2, K6921-2, K6922-2, K6923-1, K6924-1, K6926-2, K7210, ASTM D1238, ISO 1133
- AUTOMATIC 1 CYCLE (Weight Change > Sample Injection > Testing > Measuring > Cleaning)
- Automatic 1 Cycle takes 15 min. ONLY, Saving Time and Space.
- Automatic Cleaning includes: Cleaning of Cylinders / Dies / Cleaning Rods.
- HIGH REPEATABILITY by Eliminating Human Error of Cleaning, Injecting Power and Timing.
- Functions and Sample Cups are Selectable.
- MFR, MFI, MVR, Flow Properties are available.
Specification
Model | No.120-SAS MELT FLOW INDEX TESTER (SEMI-AUTOMATIC) |
Hanging | 1 or 3 Hangings (2 kinds) |
Die | φ2.095 ± 0.005 mm, L8.000 ± 0.025 mm |
Piston | Head Diameter φ9.474 ± 0.007 mm, Head Length L6.35 ± 0.10 mm |
Cylinder | Inner φ9.550 ± 0.007 mm, L160 mm |
Temperature Range | Max. 300 °C (Option: Max. 400 °C) |
Initial Weight | 0.325 kgf |
Additional Weight | 1.20 〜 21.60 *Please refer to below |
Test Method | Method A: Manual (Option: Automatic Cutter) Method B: Automatic |
Specimen Feeding | Automatic |
Weight Loading | Automatic |
Weight Change | Manual (Option: Automatic) |
Cylinder Cleaning | Automatic *Solvent Cleaning is also Automatic |
Die Cleaning | Automatic |
Piston Cleaning | Manual (Option: Automatic) |
Die Cleaning Rod' Cleaning | Manual (Option: Automatic) |
Cleaning Gauze Feeding | Manual |
Data Processing | Method A: Manual (Option: Automatic Cutter) Method B: Automatic |
Method B Measuring | Rotary Encoder |
Software | Windows Compatible |
Accessories | Cleaning Rod (Die, Cylinder), Solvent Cleaning Device, Specimen Cup, Cup Holder, Infundibulum, Die Gauge, Spirit Level, Dust Box, Gauze, Air Gun |
Options | Hastelloy Spec, Specimen Purging Device, Specimen Drying Device, Air Compressor, Temperature Calibration Device, Exhaust Fan (Standard for No.120-LABOT), Smoke-Detection Sensor (Standard for No.120-LABOT) Additional Weight ( 1.20, 2.16, 3.80, 5.00, 10.00, 21.60 kgf.) |
Power Source | AC 200 V, 1-Phase, 10 A, 50/60 Hz AC 200 V, 1-Phase, 15 A, 50/60 Hz (ISO 1133-2 Compatable Type) |
Air Source | 0.5 MPa or More |
Dimensions / Weight (approx.) |
1 Hanging: W675 × D645 × H1,370 mm, 200 kg (W2.22 × D2.12 ×H4.50 ft, 441 lbs) 3 Hangings: W675 × D725 × H1,370 mm, 220 kg (W2.22 × D2.38 ×H4.50 ft, 485 lbs) |
The specifications above are subject to change without notice.
No.120-LABOT MELT FLOW INDEX TESTER (FULLY AUTOMATIC)
Related Test Standards: JIS K6719-1/2, K6921-2, K6922-2, K6923-1, K6924-1, K6926-2, K7210, ASTM D1238, ISO 1133
- FULLY AUTOMATIC CYCLE (Weight Change > Sample Injection > Testing > Measuring > Cleaning)
- MAX 50 SAMPLE CUPS / 12.5 HOURS Automatic Cycle, Saving Time and Space.
- Automatic Cleaning includes: Cleaning of Cylinders / Dies / Cleaning Rods.
- HIGH REPEATABILITY by Eliminating Human Error of Cleaning, Injecting Power and Timing.
- Functions and Sample Cups are Selectable.
- MFR, MFI, MVR, Flow Properties are available.
Examples of Use
1 CYCLE/SAMPLE = 15 MIN.12 Hangings (Sample Cups) | |||
---|---|---|---|
AM: 12 Samples x 15 min = 3 Hours + PM: 12 Samples x 15 min = 3 Hours + Night Mode *Set before going home: 12 Samples x 15 min = 3 Hours |
36 Samples / 9 Hours per Day ! |
||
24 Hangings (Sample Cups) |
|||
AM: 12 Samples x 15 min = 6 Hours + PM: 12 Samples x 15 min = 6 Hours + Night Mode *Set before going home: 24 Samples x 15 min = 6 Hours |
72 Samples / 18 Hours per Day ! |
||
50 Hangings (Sample Cups) |
|||
50 Samples x 15 min = 12.5 Hours (96 Samples x 15 min = 24 Hours) |
Best Solution for a 24 Hours Test Lab ! |
Specification
Hanging (Sample Cup) | 12 or 24 or 50 Hangings (3 kinds) |
Die | φ2.095 ± 0.005 mm, L8.000 ± 0.025 mm |
Piston | Head Diameter φ9.474 ± 0.007 mm, Head Length L6.35 ± 0.10 mm |
Cylinder | Inner φ9.550 ± 0.007 mm, L160 mm |
Temperature Range | Max. 300 °C (Option: Max. 400 °C) |
Initial Weight | 0.325 kgf |
Additional Weight | 1.20 〜 21.60 *Please refer to below |
Test Method | Method A: Manual (Option: Automatic Cutter) Method B: Automatic |
Specimen Feeding | Automatic |
Weight Loading | Automatic |
Weight Change | Manual (Option: Automatic) |
Cylinder Cleaning | Automatic *Solvent Cleaning is also Automatic |
Die Cleaning | Automatic |
Piston Cleaning | Automatic |
Die Cleaning Rod' Cleaning | Automatic |
Cleaning Gauze Feeding | Automatic |
Data Processing | Method A: Manual (Option: Automatic Cutter) Method B: Automatic |
Method B Measuring | Rotary Encoder |
Software | Windows Compatible |
Accessories | Cleaning Rod (Die, Cylinder), Solvent Cleaning Device, Specimen Cup, Cup Holder, Infundibulum, Die Gauge, Spirit Level, Dust Box, Gauze, Air Gun |
Options | Hastelloy Spec, Specimen Purging Device, Specimen Drying Device, Air Compressor, Temperature Calibration Device, Exhaust Fan, Smoke-Detection Sensor Additional Weight ( 1.20, 2.16, 3.80, 5.00, 10.00, 21.60 kgf.) |
Power Source | AC 200 V, 1-Phase, 10 A, 50/60 Hz AC 200 V, 1-Phase, 15 A, 50/60 Hz (ISO 1133-2 Compatable Type) |
Air Source | 0.5 MPa or More |
Dimensions / Weight (approx.) |
12 or 24 Hangings: W950 × D680 × H1,720 mm, 350 kg (W3.12 × D2.23 ×H4.50 ft, 772 lbs) 50 Hangings: W1,100× D700 × H1,750 mm, 400 kg (W3.61 × D2.30 ×H5.74 ft, 882 lbs) |
The specifications above are subject to change without notice.