Digital Vibration Controllers
D-59 Series Digital Vibration Controllers for Windows 10, which can be used for not only Electro-dynamic Shakers but also Hydraulic Shakers, are featured by user-friendly usability thus enabling complicated vibration tests to be carried out easily as well as a variety of control functions available such as Sine, PSD Random, Shock, Mixed Mode, RSTD, Waveform Reproduction etc. and also input channels being expandable up to 8.
Two Main Controllers with High Expandability
By relevant license keys as options, the controllers can be expanded to the other control functions, increase in input channels (in a unit of 2 channels - for the D-0960 additional hardware also needed).
D-59 Series
・Single-axis Control・Multi-axis Sequential Control
Input: 4 channels as standard, expandable up to 8 channels
Output: 1 channel for control & COLA output as option
D-0960 Series
・Multi-axis Simultaneous & Sequential Control・Single-axis Control
Input: 6 channels (for 3-axis), 4 channels (for 2-axis) as standard
Output: 3 channels (for 3-axis), 2 channels (for 2-axis) as standard
Easy Operation
"The easier, the better!" - required for any Controllers: Featured by easy-to- recall test patterns used often and also easy-to-change test conditions or make new test patterns for everyone.
A Variety of Add-on Software Available
- Resonance Search, Track & Dwell (RSTD)
RSTD performs a resonant frequency tracking and dwell in real time, suited to fatigue tests. - Sine on Random Control (SoR)
SoR, combining fixed or swept sine tones with broad-band random vibration, is used for simulation of rotating devices of vehicles (automotive power trains, helicopters etc.) - Random on Random Control (RoR)
RoR is such control as combining narrow bands of random vibration with broad-band random vibration. - Shock Response Spectrum (SRS)
SRS, Integrated with classical shock and transient shock, is also available.
Sine Control
D-59 Series | D-0960 Series | |
---|---|---|
Control Output Axes | 1 axis | 1-12 axis choice |
Frequency Range | Standard:1 to 4000Hz Low frequency option:from 0.1Hz High frequency option: up to 10,000Hz | Standard:1 to 4000Hz Low frequency option:from 0.5Hz High frequency option: up to 10,000Hz |
Dynamic Range | up to 95dB | up to 90dB |
Control Accuracy | ±1dB(Q=50,1oct/min) | |
Test Mode | Sweep,Dwell,Oscilator | |
Control Mode | 1 channel or multi channel control Selectable among average, maximum, and minimum. |
Random Control
D-59 Series | D-0960 Series | |
---|---|---|
Control Output Axes | 1 axis | 1-12 axis choice |
Control Frequency | up to 4,680Hz (option : 18,750Hz) | |
Control Lines | 100, 200, 400, 800, 1600 and 3200 lines (option : 6400 lines) | |
Control Dynamic Range | up to 90dB | |
Control Accuracy | ±1dB (200DOF, Reliability : 99%) | |
Control Mode | 1 channel or multi channel control Selectable among average, maximum, and minimum |
Shock Control
D-59 Series | D-0960 Series | |
---|---|---|
Control Output Axes | 1 axis | 1-12 axis choice |
Data Point | up to 16,386 | |
Pulse Types | Half-sine, Initial and terminal peak saw-tooth, Triangle, Trapezoid and Haver-sine | |
Pulse Duration | Selectable in second unit | |
Test Level | Setting of test level and pulse numbers |
Transient Time History Control (TTH)
Up to 32k points waveform time-domain data can be imported into the Controller and be simulated, most suited to:
・Transient Phenomenon Simulation Against Trouble Events
・Seismic Simulation
・Collision Simulation
Road Simulation (LTH-Long Time History Control)
For longer waveform simulation (longer than 32k points), LTH Road Simulation software Is also available.