ANRITSU Fiber Optic Thermometer / Model FL series
![ANRITSU Fiber Optic Thermometer / Model FL series](../images/products/anritsu/thermometer/fl_01.jpg)
The products in the FL Series can measure temperatures in environments subject to high-frequency waves, microwaves, or high voltages-areas where electric thermometers such as thermocouples, platinum resistance temperature detectors, and thermistors are typically ineffective.
Features
- Capable of measurements in environments subject to high-frequency waves or high voltages.
- A fiber optic thermometer offering a wide measurement range.
- Analog output capability allows use for machine temperature control.
- Measurement data can be imported into a PC using software* bundles with the thermometer.
* for Microsoft® Windows® 7, Windows® 8.1, Windows® 10 (for English)
* All PCs under the recommended environment are not guaranteed to work successfully with AMS-850.
* AMS-850 can be used only by the user that has a system administrative right (Adoministrator)
* AMS-850 does not support Mac OS.
* Microsoft® Windows® 7, Windows® 8.1, Windows® 10, and Excel® are registered trademarks of Microsoft Corporation in the United States and other countries.
Applications
Semiconductor / Electronics Industry
![Semiconductor / Electronics Industry](../images/products/anritsu/thermometer/fl_app_1.jpg)
Temperature measurements of PCBs in plasma for semiconductor manufacturing equipment or reliability testing of live electric circuit components
Power Industry
![Power Industry](../images/products/anritsu/thermometer/fl_app_2.jpg)
Accident prevention and maintenance of power transformer coils, high voltage lines, generators, and other power company facilities
Material Industry
![Material Industry](../images/products/anritsu/thermometer/fl_app_3.jpg)
Temperature control during heating, drying, disinfection of wood, ceramics, fibers, plastics, and other materials, or temperature measurement of microwave organic synthesis
Food Industry
![Food Industry](../images/products/anritsu/thermometer/fl_app_4.jpg)
Development of ready-to-ent microwave food or microwaveable packaging materials; temperature controls for disinfection or drying processes based on microwaves
Medical Industry
![Medical Industry](../images/products/anritsu/thermometer/fl_app_5.jpg)
Animal tests using hyperthermia equipment or MRI or NMR systems
Specifications
1ch. FL-2000 Specifications
Type | FL-2000 | |
---|---|---|
Input point | 1 | |
Measurement range | -195.0°C to 450°C | |
Resolution | 0.1°C | |
Accuracy | Calibration not executed | -195.0 to 399.9°C : ±2°C, 400.0 to 450.0°C : ±5°C |
Calibration executed | ±0.5°C (within ±50°C of caribration point) (at an ambient temp. of 25°C±5°C) |
|
Temperature coefficient | ±(0.01% of F.S./°C) within operating temperature | |
Operating environment | Temperature : 0 to 40°C Humidity : 15 to 80%RH(non-condensing) |
|
Storage environment | Temperature : -10 to 50°C Humidity : 10 to 85%RH(non-condensing) |
|
Display | Height of character : 15mm RED LED | |
Display update | 1s | |
Light source | Blue LED | |
Power supply |
AC power | Please specify a supply voltage when ordering (choose from 100VAC, 115VAV, or 230VAC) |
Dry battery | six AA-size alkaline batteries | |
Power consumption | approx. 12 VA | |
Memory | UP to 15,000 data, one second interval (synchronized with display) |
|
Interface | RS-232C Transfer rate : 9600bps Data formation : 7bit, odd parity, 1 stop bit |
|
Calibration | One-point calibration (using real temperature within a measured area) |
|
Analog output | Output rate | 10mV/°C |
Resolution | 1mV | |
Accuracy | ±(0.2% of F.S) at an ambient temperature of 25°C±5°C | |
Temperature coefficient | ±(0.01% of F.S/°C) | |
External dimensions | 210(W)×88(H)×230(D) mm Protruded parts excluded |
|
Weight | aoorox. 3kg | |
Supplied accessory | Power cable(two-wire plug attached)×1 Fuse(2A mini fuse)×1 Analog output cable×1 communication cable×1 PC software AMS-850 (CD ROM)×1 User's manual(main unit and software)×1 |
4ch. FL-2400 Specifications
Type | FL-2400 | |
---|---|---|
Input point | 4 | |
Measurement range | -195.0°C to 450°C | |
Resolution | 0.1°C | |
Accuracy | Calibration not executed | -195.0 to 399.9°C : ±2°C, 400.0 to 450.0°C : ±5°C |
Calibration executed | ±0.5°C (within ±50°C of caribration point) (at an ambient temp. of 25°C±5°C) |
|
Temperature coefficient | ±(0.01% of F.S./°C) within operating temperature | |
Operating environment | Temperature : 0 to 40°C Humidity : 15 to 80%RH(non-condensing) |
|
Storage environment | Temperature : -10 to 50°C Humidity : 10 to 85%RH(non-condensing) |
|
Display | Height of character : 8mm RED LED | |
Display update | 1s | |
Light source | Blue LED | |
Power supply | Please specify a supply voltage when ordering (choose from 100VAC, 115VAV, or 230VAC) |
|
Power consumption | approx. 40 VA | |
Memory | No memory | |
Interface | RS-232C Transfer rate : 9600bps Data formation : 7bit, odd parity, 1 stop bit |
|
Calibration | One-point calibration (using real temperature within a measured area) |
|
Analog output | Output rate | 10mV/°C |
Resolution | 1mV | |
Accuracy | ±(0.2% of F.S) at an ambient temperature of 25°C±5°C | |
Temperature coefficient | ±(0.01% of F.S/°C) | |
External dimensions | 320(W)×99(H)×280(D) mm Protruded parts excluded |
|
Weight | approx. 5kg | |
Supplied accessory | Power cable(two-wire plug attached)×1 Fuse(2A mini fuse)×1 Analog output cable×4 communication cable×1 Conversion cable(RS-232C→USB) PC software AMS-850 (CD ROM)×1 User's manual(main unit and software)×1 |
Fiber probes
How to order of Fiber probes
It can be chosen the length of cable and Teflon coating to suit the purposes of specific your application.
Replace the asterisk (*) in the model with selectable number.
![order1](../images/products/anritsu/thermometer/fl_orderno_fs1.gif)
![order2](../images/products/anritsu/thermometer/fl_orderno_fs2.gif)
![]() |
Cable length (Specify a cable length in 1m increments.) |
2 | 2m |
3 | 3m | ||
... | ... | ||
![]() |
Teflon coating length (Specify a Teflon coating length in 0.1m increments, MAX.length : 1m) |
01 | 0.1m |
05 | 0.5m | ||
10 | 1m |
* The length of a fiber probe will be short after repar when the optical fiber is broken.
FS100-*M
Applications involving microwaves, high magnetic fields, certain food preparation processes, power lines, and electric circuit components.
![FS100-*M](../images/products/anritsu/thermometer/fl_fs100.gif)
General-purpose type
temp. range : -190°C to 260°C
FS150-*M
The durable type which sensing part of FS100 made of the same thickness as the cable.
![FS150-*M](../images/products/anritsu/thermometer/fl_fs150.gif)
High durability general-purpose type
temp. range : -190°C to 260°C
FS100H-**-*M
Oils or chemicals.
![FS100H-**-*M](../images/products/anritsu/thermometer/fl_fs100h.gif)
Liquid and chemical-resistant type
temp. range : -190°C to 260°C
FS150H-**-*M
The durable type which sensing part of FS100H made of the same thickness as the cable.
![FS150H-**-*M](../images/products/anritsu/thermometer/fl_fs150h.gif)
High durability liquid and
chemical-resistant type
temp. range : -190°C to 260°C
FS200-*M
Chemicals
![fl_fs200.gif](../images/products/anritsu/thermometer/fl_fs200.gif)
Chemical-resistant type
temp. range : -30°C to 200°C
FS300-*M
Measurements performed in laser beam, plasma, or other intense light
![fl_fs300.gif](../images/products/anritsu/thermometer/fl_fs300.gif)
Light-resistant type
temp. range : -190°C to 260°C
FS400-*M
Various materials, excluding liquids, in semiconductor manufacturing equipment or microwave heating devices
![fl_fs400.gif](../images/products/anritsu/thermometer/fl_fs400.gif)
High temperature type
temp. range : 20°C to 400°C
FS500-*M
Semisolid substances, e.g., food
![fl_fs500.gif](../images/products/anritsu/thermometer/fl_fs500.gif)
Needle type
temp. range : -60°C to 260°C
FS600-*M
Animal tests using hyperthermia equipment or MRI or NMR systems
![fl_fs600.gif](../images/products/anritsu/thermometer/fl_fs600.gif)
Plastic type
temp. range : 0°C to 80°C
FS600 series is non-repairable.
Optional accessories
Extension cable FK1-*M
![Extension cable FK1-*M](../images/products/anritsu/thermometer/fl_op_fk1.gif)
General-Purpose extension cable for normal use.
Extension cable FK2-*M
![Extension cable FK2-*M](../images/products/anritsu/thermometer/fl_op_fk2.gif)
Heavy-duty extension cable for rough environments.
- Replace the asterisk (∗) in the model number with a cable length in meters.
- Extension cable is made of Silica fiber. The extension cable cannot be used with FS600-∗M(plastic fiber).
- FA1(Optical adapter) is required for the connection of fiber sensors and relay cables.
- The length of a fiber probe will be short after repar when the optical fiber is broken.
Optional adapter FA1
![Optional adapter FA1](../images/products/anritsu/thermometer/fl_op_fa1.gif)
Con connect a probe to an extension cable.
Non-repairable
Compression fitting FN1-T / FN1-V
![Compression fitting FN1-T / FN1-V](../images/products/anritsu/thermometer/fl_op_npt_all.gif)
Compression fitting used to insert probe
into a vacuum device or pressure vessel.
FN1-T
(sealant material : TFE)
FN1-V
(sealant material : Viton)
Non-repairable
* Pressure rating : 1.33×10-4Pa to 11.0MPa at 20°C using stainless steel rod
Device for the microwave oven with a turntable
![turntable](../images/products/anritsu/thermometer/fl_op_turntable.gif)
Special order product