Sunshine Weather Meters
S300 / S80 / S80D / S80L / S80H / S80B / S80BR / S80BBR / S80-2D
Light Source : Sunshine Carbon Arc
Sunshine Weather Meters are designed to reproduce outdoor and indoor deterioration factors such as sunlight, high and low temperature, rainfall and dew in short period of time. The Sunshine Carbon Arc has been studied for long years globally and accumulated big data, as many testing standards require.
Related Standards : ISO 4892-1, ISO 4892-4, ISO 11431, ISO 16474-1, ISO 16474-4, ISO 2135, ISO 3917, ISO 17398, ASTM G 151, ASTM G 152, ASTM D822, ASTM D 3361, ASTM D750, AATCC TM192, SAE J2020, JIS K 7350-1, JIS K 7350-4, JIS K 5981,JIS A 1415, JIS A 1439, JIS K 5701-1, JIS L 0891, JIS H 8685-1, JIS A 5759, JIS K 6266, JIS K 6404-4, JIS D 0202, JIS D 0205, JIS D 5500, JIS D 4604, JIS Z 0237, JIS Z 1528, JIS E 4037, JIS Z 9107, JIS Z 9117, JIS B 7753
*Subject to the accessories.
Sunshine Weather Meter S300
- Automatic Carbon Arc Refill System with the robot arm
- Max. 12 days / 300 hours continuous operation.
- Air curtain between the carbon rods and glass filter prevents from ashes
- Irradiance 255W/m2 ±10% at 300 to 700nm
- Specimen Capacity: 69 pcs(150x70x1mm)
- Temp. and Hum. range : BPT63±3℃, Hum.30~70±5%rh
- Low temp. model S300L (CAT17℃) as an option.
- High temp. model S300H (BPT95℃) as an option.
- Wide variety of options and customization is available.
Sunshine Weather Meter S80
- Max. 78 hours continuous operation.
- Irradiance 255W/m2 ±10% at 300 to 700nm
- Specimen Capacity: 69 pcs (150x70x1mm)
- Temp. and Hum. range : BPT63±3℃, Hum.30~70±5%rh
- Dew cycle model S80D is an option.
- Low temperature model S80L (chamber temperature 17℃) is an option.
- High temperature model S80H (BPT 95℃) is an option.
- Automatic BPT control model S80B is an option.
- BPT recording model S80BR is an option.
- Both Automatic BPT control and BPT recording model S80BBR is an option.
- Wide variety of options and customization is available
Sunshine Weather Meter S80-2D
- Two Independent chambers both Sunshine Carbon Arc.
- Max. 78 hours continuous operation.
- Irradiance 255W/m2 ±10% at 300 to 700nm
- Specimen Capacity: 138 pcs (150x70x1mm) *69 pcs per each chamber.
- Temp. and Hum. range : BPT63±3℃, Hum.30~70±5%rh
- Wide variety of options and customization is available.
Standard Features
Name | Sunshine Weather Meter | ||||
---|---|---|---|---|---|
Model | S300 | S80 | S80-2D | ||
Light Source | Sunshine Long-Life Carbon Arc Lamp | Sunshine Long-Life Carbon Arc Lamp | Sunshine Long-Life Carbon Arc Lamp | ||
Light Source Qty. | 1 pair | 4 pairs | 8 pairs (4 pairs per chamber) | ||
Continuous Lightning Time | 300 hours | 78 hours | 78 hours | ||
Irradiance | Wavelength 300 to 700nm | 255W/m2±10% | 255W/m2±10% | 255W/m2±10% | |
Test Item | Light | 〇 | 〇 | 〇 | |
Light + Spray on front face (Rain) | 〇 | 〇 | 〇 | ||
Dark | - | - | - | ||
Dark + Spray on back face (Dew) | - | - | - | ||
Temperature / Humidity Range |
Light | BPT | 63±3℃ | 63±3℃ | 63±3℃ |
Humidity | 30~70±5%rh | 30~70±5%rh | 30~70±5%rh | ||
Light + Spray on front face (Rain) | Chamber Temperature (CAT) | not controlled | not controlled | not controlled | |
Dark | Chamber Temperature (CAT) | - | - | - | |
Humidity | - | - | - | ||
Dark + Spray on back face (Dew) | Chamber Temperature (CAT) | - | - | - | |
Specimen Capacity | excl. black panel sensor and light receptor | 69 (150x70x1mm) | 69 (150x70x1mm) | 138 (150x70x1mm) *69 per chamber | |
Specimen Holder | Inclined type | 35 | 35 | 70 (35 per chamber) | |
Specimen Rack | Diameter | φ960mm (37.8in) | φ960mm (37.8in) | φ960mm (37.8in) per chamber | |
Rotation Speed | 1rpm | 1rpm | 1rpm | ||
Electrical Specifications | 50/60Hz | 3 phase, 200V, 51A | 3 phase, 200V, 39A | 3 phase, 200V, 39A per chamber | |
Earth Leakage Breaker (ELB) | ELB: 60A | ELB: 50A | ELB: 50A per chamber | ||
Water Consumptions | For wet bulb pot | Tap water | approx. 0.5L/h | approx. 0.5L/h | approx. 0.5L/h per chamber |
For humidifier | Pure water | approx. 7L/min | approx. 7L/min | approx. 7L/min per chamber | |
For specimen spray | Pure water | approx. 25L/h (at 12min spray while 60min) |
approx. 25L/h (at 12min spray while 60min) |
approx. 25L/h (at 12min spray while 60min) per chamber |
|
For wall cooling and back spray | Tap water | - | - | - | |
For chamber temp. control / refrigerator |
Cooling tower water | - | - | - | |
Outer Dimensions | Width x Depth x Height (including pipings) approx. | 170x156x240cm (66.9x61.4x80.7in) | 136x145x226cm (58.3x68.9x94.5in) | 227x180x233cm (89.4x70.9x91.7in) | |
Operating Weight | approx. | 940kgs (2072lbs) | 560kgs (1235lbs) | 1200kgs (2646lbs) | |
Standard Accessories | Radiometer for Irradiance Calibration | Optional | Optional | Optional | |
Irradiance Automatic Control System | - | - | - | ||
Black Panel Temperature Automatic Control System | Optional | Optional | Optional | ||
Others | - | - | - |
***The specifications above are subject to change without notice.