Voltage Dip & Swell Simulator VDS-2002
Features
Used to evaluate performance such as malfunctions and functional deterioration due to power supply voltage fl uctuations in electronic and electrical equipment.
Simulates the phenomenon of voltage variations and momentary power failures in commercial power supplies (AC100/200V) and evaluates the resistance of electronic equipment.
In addition to the requirements of the international standard IEC61000-4-11, it is tested in all industries as a tolerance evaluation against voltage variations and instantaneous interruptions for electronic equipment.
- Voltage dip & swell simulator conforming to EN/IEC61000-4-11 Ed.3 (2020) Standard.
- Multiple types AC plug receptacle on the front panel for easy connection of the EUT.
- Easy settings for the test parameters on the front panel (Voltage variations test is performed by software.).
- Realize fl exible test conditions setting beyond the Standard with a PC remote control.
- Allows to conduct the interruption test in DC (DC 125 V / 16 A max).
Specification
| Parameter | Specification | ||||
|---|---|---|---|---|---|
| Compliant Standard | IEC 61000-4-11 (1994), IEC 61000-4-11 (2004) at Output voltage 0 to 100% | ||||
| Number of Phases | Single Phase | ||||
| Test Modes | AC/DC Voltage Interruption test Sensing, direct mode | Cycle synchronous/asynchronous setting | PC setting | Short/Open modes selection during interruption | |
| Cycle synchronous setting | Main Unit setting | Short mode during interruption | |||
| AC voltage dip and swell test Cycle synchronous/asynchronous setting | Cycle synchronous/asynchronous setting | PC setting | |||
| Cycle synchronous setting | Main Unit setting | ||||
| AC voltage variations test Sensing mode | Cycle asynchronous setting | PC setting Main Unit setting (2s, 1s, 2s setting only) |
|||
| EUT | Input voltage range | AC90~264V 50/60Hz, DC0~125V ※3 | |||
| Output voltage range | AC0V~input voltage+20%, DC0V~input voltage AC290Vmax ※2 | ||||
| Output VA rating | 4.224kVA (continuous) | ||||
| Output current capability | AC | 100% of input voltage | 16Arms (continuous)) | ||
| 80% of input voltage | 20Arms (<5s) | ||||
| 70% of input voltage | 23Arms (<5s) | ||||
| 40% of input voltage | 40Arms (<5s) | ||||
| DC | 16A (continuous) | ||||
| MAX Output current capability | AC100~120V | 250A peak Output voltage 100%, <10ms in direct mode | |||
| AC220~240V | 500A peak Output voltage 100%, <10ms in direct mode | ||||
| Load regulated Output voltage variation | 100% of input voltage 0-16 Arms | <5% | |||
| 70% of input voltage 0-23 Arms | <5% | ||||
| 70% of input voltage 0-23 Arms | <5% | ||||
| 100% of input voltage 0-40 Arms | <5% | ||||
| Overshoot / undershoot | <5% 100 ohm loaded in the Sensing Mode | ||||
| Rise time / fall time | 1~5μs 100 ohm loaded | ||||
| Parameter | Specification | |||
|---|---|---|---|---|
| BASE VOLTAGE | Percent Setting | PC setting | (4%)~120% percentage with a minimum value of 10V ※1 ※2 | |
| main unit setting | 100% ※1 | |||
| Voltage Setting | PC setting | 10~290V (0V~input voltage+20%) 5Vstep ※2 arbitrary setting 1V step |
||
| Accuracy | ±5V Output current 0 to 16A | |||
| TEST LEVEL (Interruption, dip, swell) | Percent Setting | PC setting | Short/Open selectable for 0% | 0~120% ※1 |
| main unit setting | Short/Open selectable for 0% | 0, 40, 70, 80, 120% 5V step ※1 | ||
| Voltage Setting | PC setting | Short/Open selectable for 0% | 0~290V (0V~5V step+20%) 5V step ※2 arbitrary setting 1V step |
|
| Accuracy | ±5V Output current 0 to 16A | |||
| REPEAT COUNT | No. of Events setting | PC setting | 1-1000 or continuous (0) 1 event step | |
| main unit setting | 1, 3, 5, 10, 30, 50, 100, or continuous(Cnt) 8 steps | |||
| INTERVAL CYCLES | CYCLE Setting | Synchronous | PC setting | 0.5~5000.5 CYCLE 0.5 CYCLE steps |
| main unit setting | 1, 3, 5, 10, 30, 50, 100, 300, 500 CYCLE, and 10s 10 steps | |||
| sSetting | Synchronous | PC setting | 1~100s 1s steps | |
| msSetting | Asynchronous | 8.3~100000.0ms(100s) 0.1ms steps | ||
| sSetting | Asynchronous | 1~36000s(10h) 1s steps | ||
| DIP CYCLES (voltage interruptions, dip cycles) | CYCLE Setting | Synchronous | PC setting | 0.01~5000 CYCLE 0.01 CYCLE steps |
| main unit setting | 0.5, 1, 5, 10, 12, 25, 30, 50, 250, 300 CYCLE 10steps | |||
| msSetting | Synchronous | PC setting | 0.1~100000.0ms (100s) 0.1ms steps | |
| msSetting | Asynchronous | 0.1~100000.0ms (100s) 0.1ms steps | ||
| sSetting | Asynchronous | 1~36000s(10h) 1s steps | ||
| Parameter | Specification | |||
|---|---|---|---|---|
| DIP PHASE (voltage interruptions, dip starting phase) | Phase Angle setting | Synchronous | PC setting | 0~360° 1°steps |
| main unit setting | 0, 45, 90, 135, 180, 225, 270, 315, 360° 9 steps (45°steps) | |||
| Time Setting | PC setting | 0~19.9ms 0.1ms steps 50Hz | ||
| 0~16.6ms 0.1ms steps 60Hz | ||||
| Voltage Variations Test | PC setting | Asynchronous | PC setting | 0.1s~10s 0.1s steps output voltage 0~120% |
| Memory capacity | PC setting | Up to 10 tests can be programmed and stored as long as the recording media such as PC HD, FD, etc. allow. | ||
| main unit setting | 5 tests | |||
| Input voltage from EUT | AC100~240V±10% 50/60Hz |
|||
| Interface | Optical interface Optional optical converter RS-232 or USB selection | |||
| Operating temperature | 15~35℃ | |||
| Operating humidity | 25~75%R.H. (no condensation) | |||
| External dimensions / Weight | (W)430×(H)745×(D)600mm (excluding protrusions) / approx.150kg | |||
| Power consumption | 120VA (AC100~240V 50/60Hz) | |||
※ 1:percent against input voltage
※ 2:not compliant to IEC 61000-4-11(1994) and IEC 61000-4-11 Ed2 (2004), ed.3 (2020) Standards when voltage output is >100%
※ 3:The input voltage must be free of distortion and voltage variations.
Front Panel
Options
Software (VDS-2002-PC) MODEL : 14-00036A
Allows standardized test settings and user-defi ned test settings.
In addition to the IEC test level, there are various setting items such as dip-up cycle, repetition cycle, interval cycle, etc., which greatly supports voltage fluctuation testing.
USB Optical Module Kit MODEL : 07-00022A
Connection adaptor used for PC remote control of the simulator.
USB optical conversion, equipped with 5m optical fiber cable.