Description

HPD-11■●▲

Please select numbers and alphabet from ■●▲ and form the part number.

  Selection Description
1 Resolution 0.1℃ -100.0 to 200.0℃ Analog output swings over the upper limit when disconnected or not connected
2 Resolution 0.1℃ -100.0 to 200.0℃ Analog output swings down the lower limit when disconnected or not connected
3 Resolution 1℃ Thermocouple type E -200 to 800℃ Analog output swings over the upper limit when disconnected or not connected
Thermocouple type K -200 to 1370℃ Same as above
4 Resolution 1℃ Thermocouple type E -200 to 800℃ Analog output swings down the lower limit when disconnected or not connected
Thermocouple type K -200 to 1370℃ Same as above
1 1mV/℃ Resolution 1℃ only
2 10mV/℃ Resolution 0.1℃ only
3 1~5V  
4 4~20mA Allowable load resistance 600Ω or less
E Thermocouple type E
K Thermocouple type K

Specification

Number of Input1 point
Signal of InputThermocouple type E or K *Other thermocouple types are available as an option.
Signal Source Resistance100Ω or less
Output Accuracy***Equivalent to ±(0.2% of measuring range) ℃
Reference Junction Compensation Accuracy ±0.3℃ (at 25 ±10℃ environment)
Temperature Coefficient ±(0.03% of measurement range) at temperatures other than 25±10℃
Linearization Method Analog linearization method (JIS C 1602-2015 compliant)
Response Time 1 second or less
Burnout Time Approx. 5 seconds, ±20% over measuring range, less than 12V
Isolation 3-port isolation (input-output-power)
Insulation Resistance Between input terminal and power supply terminal: 100 MΩ or more/DC500V
Between input and output terminals: 100 MΩ or more/DC500V
Power-supply Voltage DC24V (±10%)  *Available other voltage as an option
Current Consumption Approx. 60mA
Mounting Method DIN rail mounting
Case Material Modified PPO resin
External Dimensions W106 × H90 × D58 mm (Approx. W4.17 x H3.54 x D2.28 in.)
Mass Approx. 250g (Approx. 0.55 lbs.)
Connection Method M3 screw terminal connection
Operating Conditions Temperature 0~40℃ (32~104℉)
Humidity within 85%RH without condensation
Standard AccessoriesOperation manual and test report (in japanese)

Output Accuracy

Measurement Range Output Accuracy
-100.0~200.0℃ 10mV/℃ ±0.6℃
1-5V ±8mV
4-20mA ±0.03mA
-100~800℃ 1mV/℃ ±2℃
1-5V ±8mV
4-20mA ±0.03mA
-100~1370℃ 1mV/℃ ±3℃
1-5V ±8mV
4-20mA ±0.03mA