SCA

Shinyei Corporation of America

  • HOME
  • PRODUCTS
    • WEATHERING, CORROSION, AND OPTICAL PROPERTIES
    • EMC EMISSION & IMMUNITY
    • DROP & SHOCK
    • VIBRATION
    • BALL BEARINGS
    • MECHANICAL & PHYSICAL PROPERTY OF MATERIALS
    • TEMPERATURE SENSING
    • ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYZERS
    • NO-DOOR ENVIRONMENTAL CHAMBERS
    • ENVIRONMENTAL & THERMAL SHOCK CHAMBERS
    • HUMIDITY, PARTICLE, AND GAS SENSING
    • CONTRACT TEST SERVICE
  • APPLICATIONS
  • NEWS
  • ABOUT
    • About SCA
    • Shinyei Group
    • SiteMap
    • Sitepolicy
    • Cookie Policy
    • Privacy Policy
    • Disclaimers
CONTACT
   
SCA

Shinyei Corporation of America

  • HOME
  • PRODUCTS
    • WEATHERING, CORROSION, AND OPTICAL PROPERTIES
      • Weather Meters
        • GX75
        • SX75
        • SX2D-75
        • S80
        • MV3000(Metal Halide Arc)
        • U48(UV Carbon Arc)
        • FUV(Fluorescent UV Lamps)
        • CCT-LXU
        • CCT-1LX
      • Light Sources
        • 7.5kW Xenon lamp & Sunlight
        • 3kW Metaling Lamp
        • Sunshine Carbon Arc
        • UV Fluorescent Lamp
        • UV Carbon Arc
      • Corrosion Test Chambers
        • CYP-90
        • CYP-120,160,200
        • CCT-1(L)
        • CCT-RX
        • STP-90V-5/CAP-90V-5
        • STP/CAP-110,120,160,200
        • Exhaust Disposal Unit
      • Optical Property Meters
        • Color Meters
        • Gloss Meters
        • Haze Meter
          • HZ-V3(DISCONTINUED)
          • HZ-V4 (NEW)
    • EMC EMISSION & IMMUNITY
      • ESD Simulator
        • IEC61000-4-2 Ed.2 Test Standard
        • ESD simulator(ESS-S3011A+GT-30RB)
          IEC61000-4-2 Ed.3 Test Standard (NEW)
        • ESD simulator(ESS-PS1+GT-31S)
          IEC61000-4-2 Ed.3 Test Standard (NEW)
        • ISO 10605 Ed.2 Test Standard
        • ISO 10605 Ed.3 Test Standard
      • Fast Transinet Burst Simulators
      • Impulse Noise Simulator
      • Lightning Surge Simulator
      • Lightning Surge Simulator for EV fast charging
      • High Voltage Noise
      • Field Decay Load Dump
      • TEM Horn Antenna
      • Thin Plate Broadband Antenna
        • Thin Plate Broadband Antenna(NKU07M32G/NKU2460G)
        • Thin Plate Broadband Antenna(NKU5080G) (NEW)
      • Electromagnetic Field Visualization System
    • DROP & SHOCK
      • Drop Test Systems
        • DT-202 series
        • DT-205 series
        • DT-20e
        • RDT-1000
        • EMH series
      • Shock Test Systems
        • HDST series
        • ASQ series
        • MDST series
        • SDST series
        • PST-300
        • CDS series
      • Material Testing System
        • ACST series
      • Acceleration Measurement
        • SM-500
        • AccStick
      • Field Data Recorder
        • DER-1000
    • VIBRATION
      • Products
      • Basics of Vibration Testing
      • Multi-Axis Vibration Test Systems
      • Single-Axis Vibration Test Systems
      • Vibration Combined Environmental Test Systems
      • Digital Vibration Controller
    • BALL BEARINGS
      • Stainless Steel Ball bearing by AFC bearings
      • Stainless Steel Ball Bearing
        • AISI 440C Stainless Steel Ball Bearings
        • AISI 304 Stainless Steel Ball Bearings
        • AISI 630 Stainless Steel Ball Bearings
        • 2C Series - Ceramic Bearings
        • Grease Free Bearings
        • 1T Series - Pure Titanium Bearings
        • SH series - Stainless Ball Bearing with Aligning Ring
        • SSXC Series - Stainless steel ball bearings with setscrews
        • SF series - AISI440C Flanged Bearing Units
      • Spherical rolling joint SRJ series
    • MECHANICAL & PHYSICAL PROPERTY OF MATERIALS
      • By Test Applications
      • By Test Properties
    • TEMPERATURE SENSING
      • Temperature Probes
        • Stationary Surface Temperature Probes
          • SX Series
          • WE Series
        • Moving/Rotating Surface
          Temperature Probes
          • U Series
        • Moving Wire / Tube Probe
        • Liquid / Semiliquid Probes (Needle type)
        • Special Application Temperature Probes
          • AW Series(for Wafer)
      • Thermometers
        • Handheld Thermometer Model HR series
        • Handheld Thermometer
        • Thermoprinter
        • Thermologger
        • Transducer (Transmitter) HPD Series
        • Non-contact thermometer
        • Soldering iron thermometer
        • Fiber optic thermometer
      • Application
      • Accessories
      • Technical Guide
      • FAQ
    • ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYZERS
      • VoXER
      • OURSTEX 170
      • OURSTEX 101FA
      • OURSTEX 100FA
      • OURSTEX 100TA-F
      • OURSTEX 200TX
      • OURSTEX 160
      • OURSTEX 160RoHS
      • OURSTEX 160M
    • NO-DOOR ENVIRONMENTAL CHAMBERS
    • ENVIRONMENTAL & THERMAL SHOCK CHAMBERS
      • Temperature and Humidity
      • Thermal Shock
      • Compact Temperature and Humidity
    • HUMIDITY, PARTICLE, AND GAS SENSING
      • Humidity Sensing
        • humidity Sensors
        • humidity and Temperature
        • Thermo-hygrometer/Recorder
        • Temperature humidity converter
        • TDLAS Moisture Analyzers
        • Humidity Generators
      • Particle Sensing
        • Particle Sensor Unit
        • Aerosol Sensor
        • Pollen Sensor
        • Large Particle Sensor
        • PM Sensor
      • IAQ Sensing
        • Handheld Odor Meter
    • CONTRACT TEST SERVICE
  • APPLICATION NOTES
  • NEWS
  • ABOUT
    • About SCA
    • Shinyei Group
    • SiteMap
    • Sitepolicy
    • Privacy Policy
    • Cookie Policy
    • Disclaimers
  • CONTACT

APPLICATION NOTE

  1. HOME
  2. APPLICATION NOTES
  3. Aluminum Surface Temperature Measurement Solutions

Aluminum Surface Temperature Measurement Solutions

Reliable contact temperature measurement for aluminum extrusion and processed aluminum parts

Aluminum surfaces can be difficult to measure accurately with non-contact infrared thermometers because of their low emissivity and reflective characteristics.
Anritsu contact temperature probes provide stable and reliable temperature measurement for aluminum extrusions, die temperature checks, heat sink testing, and processed aluminum parts.

Aluminum die for extrusion and processing
Machining of an aluminum surface

Application Examples

Aluminum extrusion profiles

  • Solid aluminum extrusions
  • Hollow aluminum extrusions
  • Semi-hollow aluminum extrusions
  • Structural aluminum extrusions
  • Architectural aluminum extrusions
  • Heat sink extrusions

Aluminum parts and components

  • Aluminum die casting dies
  • Aluminum enclosures
  • Heat sinks and thermal components
  • Electronic component heat dissipation testing

Why Contact Measurement Is Recommended for Aluminum

Aluminum has low emissivity and highly reflective surface characteristics. As a result, infrared thermometers may produce unstable or inaccurate readings unless emissivity is carefully corrected.

Contact temperature probes measure the surface directly, making them especially useful when surface conditions vary due to:

  • Oxidation
  • Surface finish
  • Lubrication
  • Processing conditions
  • Shape variation
  • Profile geometry

For many aluminum applications, contact measurement provides more reliable and repeatable results.

Measurement Challenges for Aluminum Surface Temperature

Point Details
High-temperature environment Aluminum extrusion processes often involve high temperatures, so it is important to select sensors with sufficient heat resistance.
Sensor pipe length When a long sensor pipe is required, the pipe length must be carefully considered. For lengths over 1 m, a special pipe joint structure, such as 1 m + 1 m, may be recommended to improve handling and transportation.
Measurement direction The relationship between the operator, the measurement surface, and the sensor direction is important for stable contact.
Point Details
Ensure firm sensor contact When the target temperature is high, it may be difficult for the operator to approach it safely.
If a pipe length is longer, it may be difficult to visually confirm whether the sensor probe is making proper contact with the target surface.

Selecting the Right Sensor Shape and Pipe angle

The sensor pipe angle should be selected according to the position of the measurement surface and the operator’s working direction.

Recommended Pipe Angle by Measurement Position

Measurement situation Recommended sensor pipe angle
The measurement surface is like a wall when viewed from the operator Straight pipe
The measurement surface is like a floor when viewed from the operator 90°pipe

This helps improve contact stability, operator safety, and measurement repeatability.

Notes for Moving Surface Measurement

When measuring a moving aluminum surface, it is important to select a sensor designed for moving surfaces.

For example, when proposing S-5* or S-6* moving-surface sensors, the direction of surface movement must be checked in advance. S-type moving-surface sensors are designed to contact the surface in a specific direction only.

Therefore, the following point must be confirmed:

  • Does the measured surface move from right to left when viewed from the operator?
  • Or does it move from left to right?

This is especially important when using a 90° pipe, because sensor contact direction and surface travel direction must be compatible.

Surface Unevenness and Sensor Contact Stability

In some cases, aluminum profiles or processed aluminum parts do not have perfectly smooth and flat surfaces. The surface may have slight unevenness, grooves, or concave areas.

If the protrusion length of the contact plate from the sensor guard is too short, the guard may touch the surrounding surface first, preventing the contact plate from reaching the actual measurement point. This can result in unstable or inaccurate temperature measurement.
For such applications, S Series and HHT Series sensors are recommended.

Solutions

Anritsu Sensor Probes provide reliable contact temperature measurement solutions for aluminum surface temperature measurement applications, including extrusion processes, die temperature checks, heat sink testing, and aluminum processed parts.

With fast response, high accuracy, and durable sensor construction, Anritsu Sensor Probes support quality control, process optimization, and preventive maintenance.

These solutions help manufacturers:

  • Reduce scrap
  • Improve productivity
  • Stabilize process conditions
  • Ensure consistent product quality
  • Improve temperature measurement reliability on aluminum surfaces

S/SX Series and HHT Series

Contact temperature measurement on an aluminum surface
Contact temperature measurement on a moving aluminum surface

S/SX Series and HHT Series probes can be customized to match the application requirements.

Customizable options include:

  • Temperature range
  • Pipe angle
  • Pipe length
  • Application-specific design
S/SX Series S-5/S-6 and
SX-5/SX-6 series
HHT Series

HR Series

HR Series thermometers

HR Series thermometers can be used with compatible Anritsu temperature probes to support accurate and reliable temperature measurement in production, inspection, and quality control environments.

HR Series

Need help selecting the right probe and thermometer?

Contact us today to discuss your aluminum surface temperature measurement application.

  • SUGA
  • NOISEKEN
  • SHINYEI
  • VIBRATION
  • BALL BEARING
  • YASUDA
  • ANRITSU
  • OURSTEX
  • ETAC
sca Shinyei Corporation of America

Head Office
1120 Avenue of the Americas,
4th Floor NewYork, NY 10036
TEL:917-484-7884 / FAX: 212-704-4206

CONTACT US
sca Shinyei Corporation of America

Mexico Liaison Office
Blvd. Bernardo Quintana No.7001,
Q7001 Torre 1 - Int. 808,
Col. Centro Sur, C.P. 76090,
Queretaro, QRO, Mexico
TEL:442-229-0767

CONTACT US
© 2018 Shinyei Corp. of America All rights reserved.